stovesonline telephone contact logo 0845 226 5754

Fitting instructions for the Dektite ezi seal roof flue flashing

Stove Help & Advice Home

These fitting instructions are for the Dektite ezi seal roof flashing.

Dektite EPDM flashing are not suited to use with single skin flue pipe as the flue gets too hot. In this situation use a Dektite high temperature flashing.
Dektite ezi seal roof flashing fitting instructions
Fitting a Dektite ezi seal roof flashing step 1 Fitting a Dektite ezi seal roof flashing step 2 Fitting a Dektite ezi seal roof flashing step 3
Trim the cone of the Ezi-Seal flashing to suit the flue pipe size. Slide the roof flashing down the flue pipe using water as a lubricant. If the flue pipe has a folded seam then once the flashing is fully installed apply a bead of silicone where this seam meets the EPDM cone to make sure that it is waterproof. Press the base of the Dektite flashing to the roof profile by hand.
Fitting a Dektite ezi seal roof flashing step 4 Fitting a Dektite ezi seal roof flashing step 5
Fasten to the roof using self-tapping fasteners or pop rivets. For enlarged holes and penetrations on steep pitched roofs up to 45 degrees or on deeply corrugated roofs use the Dektite Ezi-Seal roof flashing on the diamond. If the flue pipe has a seam in it then apply silicone where the seam meets the cone of the Ezi-Seal flashing.


Fastening methods

Types of roofs suitable for Dektite Ezi-Seal roof flue flashing
Dektite Ezi-Seal roof flue flashing fastening points 1 The Dektite Ezi-Seal flashing seals by compression, so ensure that the fastenings are evenly distributed (approximately every 40mm) around the base. It is also essential that fastenings are placed in any valleys created when the flashing forms around a ridge on the roof.

Dektite Ezi-Seal roof flue flashing fastening points 2 On some roof profiles an extra fastening is needed if there is an indent at the top of a ridge, as shown if the diagram to the right.


  • Use 10x16 Hex head self-drilling fasteners.
  • After screw fixing the base, flatten the aluminium between the fixings to compress the foam.
  • Always install a fixing into the corners of the profile to fully seal against the sheet.
  • Make sure the foam is compressed by at least 40% all the way around to ensure an effective seal.

Fixing kits for dektite flashings

Fixing kits are available for the dektite ezi-seal flashing. There are two sizes of fixing kit small (KIT 1) and large (KIT 2).

In KIT 1 there is: 1 x 75ml tube of Silicone, 25 x Self Drilling Screws, 25 x colour caps (Silver) and 1 x fixing instruction leaflet. Kit 1 costs 9.25 inc VAT.

In KIT 2 there is: 3 x 75ml tube of Silicone, 75 x Self Drilling Screws, 75 x colour caps (Silver) and 1 x fixing instruction leaflet. KIT 2 costs 12.75 inc VAT.

stovesonline are members of regensw stovesonline are members of the LILI network stovesonline saving on C02
pay for your stove by visa pay for your stove by mastercard pay for your stove by maestro pay for your stove by delta card


Stovesonline Ltd, Flightway, Dunkeswell Business Park , Dunkeswell , Devon , EX14 4RD
0845 226 5754, info@stovesonline.co.uk, Contact Us
© Stovesonline Ltd. VAT: 801261871, Company: 04636920. Registered in England, UK