| Seldek Aluminium roof flashing fitting instructions | |||||
![]() |
![]() |
![]() |
|||
| Read down the cone of the Seldek aluminium flashing to determine the correct cutting ring for the flue diameter, and then trim the cone to suit using sharp tin snips. | Slide the flashing down the flue pipe using water as a lubricant. | Place the upper edge of the base under the roof tiles forming and anti-capillary fold. | |||
![]() |
|||||
| Cut tabs and press and tab the bottom corners to form a soaker run off tray. Important: cut tabs and turn them under the tile at the base of the flashing for stability. Trim as required | For flue pipe with seams apply silicone where the seam meets the cone of the flashing. | ||||