Ventilating Selkirk twin wall flue when boxing in

When a non-ventilated ceiling support is used (safer than using a ventilated one) then 4 ventilation grilles must be used to ventilate the boxing in. This stops the heat within the boxing from building up and as an added bonus recovers heat that would otherwise be wasted.

selkirk stc ventilation grille

Two grilles must be placed opposite each other at the bottom of the boxing in with the grille vents pointing downwards. Two more must be placed opposite each other at the top of the boxing in. If the boxing in is in a corner of a room then the grilles may be placed on adjacent sides of the boxing in.

selkirk stc ventilation grille orientation

selkirk stc boxing in ventilation grille

When do you have to box in

Read about when you have to box in twin wall flue in our building regulations section.

stovesonline are members of regensw stovesonline are members of the LILI network stovesonline saving on C02
pay for your stove by visa pay for your stove by mastercard pay for your stove by maestro pay for your stove by delta card

Stovesonline Ltd, Flightway, Dunkeswell Business Park , Dunkeswell , Devon , EX14 4RD
0845 226 5754 | | 01803 864561,, Contact Us
© Stovesonline Ltd. VAT: 801261871, Company: 04636920. Registered in England, UK