The LTC series load units consist essentially of a pump, and a 3-way valve controlled by a thermostat, and a thermosyphon bypass. A flue thermostat detects when the stove is running and starts the pump in the load unit. We recommend a flue thermostat as opposed to a pipe stat because the temperature of the flue pipe is a much better indicator of whether the stove is going or not: the water in a system can stay hot long after the stove has gone out.
While the water in the stove is below 60ºC the valve remains closed and the water is only pumped through the backboiler in the stove. This volume of water is very small and so quickly heats up. The thermostat in the unit begins to open the valve when the water reaches 60 ºC, allowing water from the stove out into the heating system. The valve is fully open at 70 ºC which means that all the water is then allowed out into the heating system.
This means that only hot water is allowed into the heating system which is especially important if you are using an accumulator tank as you only want to allow hot water into the tank, otherwise you risk cooling your tank. Whilst the water is being heated from 60ºC to 70ºC the valve is gradually opening so the flow into the system increases gradually as the temperature does - again this reduces potential cooling of the tank through mixing.
If the power fails or the pump fails then the LTC series load unit still allows for thermosyphoning which is very important as it means that the water in the boiler should not overheat, and your system may even continue to provide heating and hot water as long as you designed it with thermosyphoning in mind.
An Esbe LTC series load unit comes with 3 thermostat dials which show the temperature of the water flowing through the unit. This allows you to visually see that the load unit is working as it should. In many smaller installations the load unit would be hidden, but it is a good idea to incorporate an inspection hatch as part of the design so you can access, inspect and service (not that the LTC should really need servicing).
The Esbe LTC143 load unit is suited for use with boilers stoves, has 28mm compression fittings making it easy to plumb in, starts to open at 60ºC and is fully open at 70ºC.
You might want to have a look at the VTC series load valves which we also supply – these are 3-way thermostatic valves which means you can use your existing central heating pump.
The price of the ESBE LTC143 stove load unit includes delivery within England, and most of Wales - click the map for more details.
Contact Stovesonline on 0845 226 5754
Any Questions:
use our enquiry system
| HEIGHT | 215 MM |
| WIDTH | 220 MM |
| DEPTH | 110 MM |
| WEIGHT | 5 kg |

![]() | If you use an accumulator tank then reducing the flow rate from the tank is very important for good stratification. Once way to do this is to use thermostatic mixer valves - either simple 3-way mixers or electronic controlled valves - to set the desired flow temperature from the tank. | ![]() | ||
For large log gasification boilers we generally advise the use of a VTC511 load valve as opposed to a load unit – this is because the load valve allows for a higher flow rate. If you do want a complete load unit for a log gasifiyer then the Esbe LTC171 load unit has internal threaded 2” fittings, starts to open at 60ºC and is fully open at 70ºC.
The price of the ESBE LTC171 log gasifiyer load unit includes delivery within England, and most of Wales - click the map for more details.
£461.75 inc VAT
Contact Stovesonline on 0845 226 5754
Any Questions:
use our enquiry system
| HEIGHT | 228 MM |
| WIDTH | 246 MM |
| DEPTH | 110 MM |
| WEIGHT | 6 kg |

![]() | Is the window on your stove tarring up? Do you not get much heat from your stove? Do you find that it runs very slowly but then suddenly gets too hot? Sounds like your firewood is too wet. You can make sure that your firewood is at or below 25% moisture with the Stovesonline moisture meter | ![]() | ||