Overheat Safety Valve Pressurised Systems

An overheat safety valve provides protection to a boiler stove that has been designed for installation onto pressurised systems.


How does this work?
The boiler stove will have a copper finned coil inside the boiler jacket, this is called a quench coil.  The over heat valve has a sensor probe which is fitted into an immersion pocket on the boiler stove, if the heat sink radiator does not get rid of the excess heat in an emergency (temperatures in excess of 97 deg C) then the valve will release cold mains water through the quench coil which will cool down the boiler temperature.

Technical specs:
3/4 Inch female valve connections
1/2 Inch male x 145mm sheath
1300mm probe length
97ºC release temperature

£135 inc. VAT In Stock Now

  • Weight2kg
1 day delivery available from just £13. For more information about deliveries, visit our delivery information page.

Get in touch

You can contact us by phone: 

  • Mainline: 0800 246 1250
  • Susi: 01803 712 316
  • Stovespares Jane: 01580 201 385

You can use our enquiry system to send us a message through the website.

Or you can email us via info@stovesonline.co.uk

Start a Flue Design

You can use our Flue Design Service to have your chimney system designed by our experts, it's all included when you choose to work with us.