Stoves Online
Stoves Online

Expansion vessels for Thermal Stores

Expansion vessels are needed when you have a sealed, or pressurised, heating system. Most new heating systems in the UK are sealed and indeed most boiler stoves and biomass boilers are installed on sealed systems on the continent. Over here there are now a growing number of boiler stoves suited to sealed systems and hence expansion vessels are needed. When a thermal store is involved the volume of water in the system becomes rather large and hence the expansion vessel volume also needs to accommodate.

An expansion vessel is essentially a metal tank, as you can see, with a balloon/membrane inside. As it warms up the water in the system expands and pushes into the balloon/membrane. When installing the system your heating engineer pumps air into the other side of the balloon/membrane to pre-charge this part of the tank. This pre-charge pressure is dependant on the height of your heating system. Essentially the higher your house is the higher the pressure will be at the base of your heating system because all that height of water is pressing down. By pre-charging the air on the other side of the membrane you ensure that there is somewhere for the water to expand into, otherwise the water would just fill full of water the moment it was connected.

The size of the expansion vessel is determined by the static pressure of the system (so the height of the whole heating system) and, most importantly, the maximum operating pressure. The maximum operating pressure of the system is decided by the element in the system with the lowest maximum operating pressure. As the water in the system heats up it expands and compresses the balloon in the expansion vessel. As the balloon compresses the air pressure in the balloon increases. We have to calculate the overall expansion vessel volume so that when the water has fully heated the pressure in the balloon is a little less than the maximum operating pressure of the system.

Our heating engineers can calculate the right size of expansion vessel for your system. You will need to tell them the total system volume, the height of your system from the lowest point to the highest point, the maximum operating pressure (so the element in the system with the lowest operating pressure), and whether the system is filled with anti-freeze. They can then do the rest.

Model Price
35L Heating Expansion Vessel Floor Standing £125.00 inc. VAT
50L Heating Expansion Vessel Floor Standing £150.00 inc. VAT
80L Heating Expansion Vessel Floor Standing £235.00 inc. VAT
105L Heating Expansion Vessel Floor Standing £365.00 inc. VAT
150L Heating Expansion Vessel Floor Standing £580.00 inc. VAT
200L Heating Expansion Vessel Floor Standing £585.00 inc. VAT
250L Heating Expansion Vessel Floor Standing £770.00 inc. VAT
400L Heating Expansion Vessel Floor Standing £1,255.00 inc. VAT
500L Heating Expansion Vessel Floor Standing £1,485.00 inc. VAT
600L Heating Expansion Vessel Floor Standing £1,795.00 inc. VAT
700L Heating Expansion Vessel Floor Standing £2,075.00 inc. VAT
800L Heating Expansion Vessel Floor Standing £3,495.00 inc. VAT
900L Heating Expansion Vessel Floor Standing £4,295.00 inc. VAT

People also bought

Clearline EPDM Flue Flashings
For profiled, flat or corrugated roofs we offer these multi-purpose Clearline EPDM flashings. These are designed for maximum weather resistance and simple installation.
Flue thermostat
Installed on your flue pipe a flue stat is an accurate way of switching your load unit pump or heating pump on when your stove is on, and switching it off when the stove has gone out.
Clearline AKW Twin Wall Flue
Available in a matt black or a stainless steel finish, Clearline AKW twin wall flue lets you quickly, and safely, make a new chimney for your stove.
High temperature header tanks
High temperature header tanks are essential for vented boiler stove installations. These copper high temperature F&E tanks can easily take temperatures in excess of 110ºC – which standard header tanks cannot.
LK 840 3 way mixer valves
LK840 3 way valves are used, with an electronic controller, to adjust the mixed temperature going to a home's heating system, or within a boiler.
LK 810 ThermoMat G load unit
£609.79 inc. VAT
LK 551 Hydromix 35-65C Mixer Valve 22mm
The LK 551 Hydromix helps to ensure that the hot water in your house is scald-safe, reduce heat losses in the pipework, and reduce mixing in your thermal store.
£109.09 inc. VAT
Overheat Safety Valve Pressurised Systems
This Overheat Safety Valve gives protection for boiler stoves installed on pressurised heating systems. If the stove overheats then mains water flushes through an internal heat exchange coil in the stove cooling it down.
£129.36 inc. VAT
Walltherm Vajolet stove
The Vajolet is the latest boiler model from Walltherm boasting an unbeatable 91% efficiency
£5,700 inc. VAT
Arikazan Ventum VG log gasification boilers
Highly efficient, robust and well designed log gasification boilers that will give you the maximum heat from your wood in a clean and controlled burn.